<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Turbidity Meter &#8211; Electronics India &#8211; Manufacturer, Supplier and Exporter of Analytical, Scientific Laboratory and Pharmaceautical Instruments in India.</title>
	<atom:link href="https://electronicsindia.co.in/products/turbidity_meter/feed/" rel="self" type="application/rss+xml" />
	<link>https://electronicsindia.co.in</link>
	<description>Wide range of Scientific, Analytical , Laboratory, Pharmaceautical instruments including Spectrophotometer, Single Beam Spectrophotometer, Double Beam Spectrophotometer, Visible Spectrophotometer, Dissolution Test Apparatus, Disintegration Test Apparatus, Moisture Tritrator, Melting Point Apparatus, Leak Test Apparatus, Flame Photometer, Nephelometer, Turbidity Meter, Fluorometer, Bulk Density, Tap Density, Potentiometer, Colorimeter, Colony Counter, pH Meter, Conductivity Meter, TDS Meter, Salinity Meter etc.</description>
	<lastBuildDate>Fri, 19 Apr 2019 10:22:07 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>Digital Turbidity Meter &#8211; 335, 331 &#038; 341</title>
		<link>https://electronicsindia.co.in/product/digital-turbidity-meter-335-331-341/</link>
		
		<dc:creator><![CDATA[Grazitti Interactive]]></dc:creator>
		<pubDate>Tue, 02 Aug 2016 05:31:22 +0000</pubDate>
				<guid isPermaLink="false">http://electronicsindia.co.in/?post_type=product&#038;p=2077</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="vc_row wpb_row vc_row-fluid product_feature_row"><div class="section clearfix grid_section "><div class="wpb_column vc_column_container vc_col-sm-6 "><div class="vc_column-inner "><div class="wpb_wrapper"><h3 style="text-align: left;font-family:Raleway;font-weight:400;font-style:normal" class="vc_custom_heading product_det_feat_heading">Features</h3>
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<ul>
<li>Reliable &amp; Accurate Results</li>
<li>Measurements upto 1000 NTU</li>
<li>3½ Digit 7-Segment LED Display</li>
<li>Sewage and Drinking Water Testing</li>
</ul>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6 "><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_single_image wpb_content_element vc_align_right    product_det_feat_img">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="300" height="300" src="https://electronicsindia.co.in/wp-content/uploads/2016/08/model-331Nw-1-300x300.jpg" class="vc_single_image-img attachment-medium" alt="" srcset="https://electronicsindia.co.in/wp-content/uploads/2016/08/model-331Nw-1-300x300.jpg 300w, https://electronicsindia.co.in/wp-content/uploads/2016/08/model-331Nw-1-150x150.jpg 150w, https://electronicsindia.co.in/wp-content/uploads/2016/08/model-331Nw-1.jpg 440w" sizes="(max-width: 300px) 100vw, 300px" /></div>
		</figure>
	</div>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="section clearfix grid_section "><div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">Clarity of water is extremely important in products destined for human consumption. Suspension free water is also considered necessary for industries manufacturing beverage, food products etc. Similarly, minimum limits of turbidity are required to be observed in drinking water &amp; sewage disposals.</p>

		</div>
	</div>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="section clearfix grid_section "><div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">Ei’s Digital Turbidity Meter and Nephelometer are ideal instruments for measurement of suspensions. They consist of a light source focused on a test tube containing the sample solution under test. The light, reflected at right angle to the focused light by the suspension in the solution, is detected by the photo electric detector, amplified and displayed on a 3½ digit LED display.</p>

		</div>
	</div>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="section clearfix grid_section "><div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner "><div class="wpb_wrapper"><h3 style="text-align: left;font-family:Raleway;font-weight:400;font-style:normal" class="vc_custom_heading">Specifications</h3>
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<div class="web-table">
<table class="table specification-table-product">
<tbody>
<tr>
<td class="table-first-row-header">Model</td>
<td class="table-first-row-header">335</td>
<td class="table-first-row-header">331</td>
<td class="table-first-row-header">341</td>
</tr>
<tr>
<td>Product</td>
<td class="tdBorder">Digital<br />
Turbidity Meter</td>
<td class="tdBorder">Digital<br />
Turbidity Meter</td>
<td>Digital<br />
Nephelometer</td>
</tr>
<tr>
<td>Range</td>
<td class="tdBorder">0 &#8211; 1000 NTU<br />
(in 4 Ranges)<br />
0 &#8211; 2, 20, 200,<br />
1000 NTU</td>
<td class="tdBorder">0 &#8211; 1000 NTU<br />
(in 2 Ranges)<br />
0 &#8211; 200, 1000 NTU</td>
<td>0 &#8211; 200 NTU<br />
(in 2 Ranges)<br />
0 &#8211; 20, 200 NTU</td>
</tr>
<tr>
<td>Resolution</td>
<td class="tdBorder">0.01 NTU</td>
<td class="tdBorder">1 NTU</td>
<td>0.1 NTU</td>
</tr>
<tr>
<td>Accuracy</td>
<td class="tdBorder">± 3% FS, ± 1Digit</td>
<td class="tdBorder">± 3% FS, ± 1Digit</td>
<td>± 2% FS, ± 1Digit</td>
</tr>
<tr>
<td>Display</td>
<td colspan="3">3½ Digit 7-Segment LED</td>
</tr>
<tr>
<td>Light Source</td>
<td colspan="3">IR LED</td>
</tr>
<tr>
<td>Detector</td>
<td colspan="3">Photodiode</td>
</tr>
<tr>
<td>Sample System</td>
<td colspan="3">60 x 25mm Clear Glass Test Tubes</td>
</tr>
<tr>
<td>Power</td>
<td colspan="3">230 V ± 10% AC, 50 Hz</td>
</tr>
<tr>
<td>Dimensions</td>
<td colspan="3">245 x 260 x 125 mm (L x B x H) (Approx.)</td>
</tr>
<tr>
<td>Accessories</td>
<td colspan="3">Test tube Set of 5, Operation Manual, Dust Cover</td>
</tr>
</tbody>
</table>
</div>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p><strong>Note :</strong> Specifications are subject to change due to continuous improvements.</p>

		</div>
	</div>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="section clearfix grid_section "><div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner "><div class="wpb_wrapper"></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="section clearfix grid_section "><div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner "><div class="wpb_wrapper"></div></div></div></div></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>