<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Dry Bath Incubator &#8211; Electronics India &#8211; Manufacturer, Supplier and Exporter of Analytical, Scientific Laboratory and Pharmaceautical Instruments in India.</title>
	<atom:link href="https://electronicsindia.co.in/products/dry-bath-incubator/feed/" rel="self" type="application/rss+xml" />
	<link>https://electronicsindia.co.in</link>
	<description>Wide range of Scientific, Analytical , Laboratory, Pharmaceautical instruments including Spectrophotometer, Single Beam Spectrophotometer, Double Beam Spectrophotometer, Visible Spectrophotometer, Dissolution Test Apparatus, Disintegration Test Apparatus, Moisture Tritrator, Melting Point Apparatus, Leak Test Apparatus, Flame Photometer, Nephelometer, Turbidity Meter, Fluorometer, Bulk Density, Tap Density, Potentiometer, Colorimeter, Colony Counter, pH Meter, Conductivity Meter, TDS Meter, Salinity Meter etc.</description>
	<lastBuildDate>Thu, 04 Apr 2019 10:14:23 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>Dry Bath Incubator 352</title>
		<link>https://electronicsindia.co.in/product/dry-bath-incubator-352/</link>
		
		<dc:creator><![CDATA[Electronics India]]></dc:creator>
		<pubDate>Mon, 11 Dec 2017 10:28:38 +0000</pubDate>
				<guid isPermaLink="false">http://electronicsindia.co.in/?post_type=product&#038;p=2980</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="vc_row wpb_row vc_row-fluid product_feature_row"><div class="section clearfix grid_section "><div class="wpb_column vc_column_container vc_col-sm-6 "><div class="vc_column-inner "><div class="wpb_wrapper"><h3 style="text-align: left;font-family:Raleway;font-weight:400;font-style:normal" class="vc_custom_heading product_det_feat_heading">Features</h3>
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<ul>
<li>16&#215;2 line alphanumeric LCD display with backlit</li>
<li>PID(Software Controlled) for temperature</li>
<li>Block is fabricated to fit in 24 test tubes of 12mm dia.</li>
<li>Supply of 230V, 50Hz, AC is available</li>
</ul>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6 "><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_single_image wpb_content_element vc_align_right   product_det_feat_img">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="300" height="300" src="https://electronicsindia.co.in/wp-content/uploads/2017/12/model-352-300x300.jpg" class="vc_single_image-img attachment-medium" alt="" srcset="https://electronicsindia.co.in/wp-content/uploads/2017/12/model-352-300x300.jpg 300w, https://electronicsindia.co.in/wp-content/uploads/2017/12/model-352-150x150.jpg 150w, https://electronicsindia.co.in/wp-content/uploads/2017/12/model-352.jpg 440w" sizes="(max-width: 300px) 100vw, 300px" /></div>
		</figure>
	</div>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="section clearfix grid_section "><div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">Dry Bath Incubator model 352 is a microcontroller based instrument  designed to control the heating of thermally conducting block. The block is fabricated to fit in 24 test tubes of 12mm dia. The test tubes contact the walls of the block to provide constant precise temperatures to the test tubes contents. The output of the heater is controlled by means of a precision temperature sensor and highly sensitive automatic electronic temperature controller.</p>

		</div>
	</div>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="section clearfix grid_section "><div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner "><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<p style="text-align: justify;">It is widely used in samples cultivation, preservation and reaction, DNA amplification, pre- degeneration of electrophoresis and solidification. It is used in the clinical, pharmaceutical, chemical, food safety, environment and quality inspection etc.</p>

		</div>
	</div>
</div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="section clearfix grid_section "><div class="wpb_column vc_column_container vc_col-sm-12 "><div class="vc_column-inner "><div class="wpb_wrapper"><h3 style="text-align: left;font-family:Raleway;font-weight:400;font-style:normal" class="vc_custom_heading">Specifications</h3>
	<div class="wpb_text_column wpb_content_element ">
		<div class="wpb_wrapper">
			<table class="table specification-table-product">
<tbody>
<tr>
<td>Block Size</td>
<td>24 holes for 12 mm test tubes</td>
</tr>
<tr>
<td>Temperature Range</td>
<td>+5°C Above ambient up to 100°C</td>
</tr>
<tr>
<td> Temperature Accuracy</td>
<td>± 2°C</td>
</tr>
<tr>
<td>Temperature Sensor</td>
<td>LM 35 (Semi Conductor)</td>
</tr>
<tr>
<td>Maximum Heating Power</td>
<td>125 W</td>
</tr>
<tr>
<td>Temperature Controller</td>
<td>PID(Software Controlled)</td>
</tr>
<tr>
<td>Timer</td>
<td>1-99 Minutes</td>
</tr>
<tr>
<td>Display</td>
<td>16&#215;2 Line Alphanumeric LCD Display</td>
</tr>
<tr>
<td>Power Supply</td>
<td>230V±10% AC, 50Hz</td>
</tr>
<tr>
<td>Dimensions</td>
<td>190 x 220 x 125mm</td>
</tr>
<tr>
<td>Weight</td>
<td>2.70  Kgs. (Approx.)</td>
</tr>
</tbody>
</table>
<p><strong>Note :</strong> Specifications are subject to change due to continuous improvements.</p>

		</div>
	</div>
</div></div></div></div></div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
